022 28691486
Email: info@ideasinfratech.com

MENU

Read More

Monitor & Maintain :            Performance &            Health of Assets
Control : Usage of Power & Resources
Reduce : Cost of Operation
Maximize : Business UP-TIME


OUTSOURCED    ATM
Improve  Revenue
•       Increase Customer Transactions
        Reduce O&M Costs
•       Improve Operational Efficiencies
•       Cost  Saving Initiatives


Battery Valued Asset
Battery is the costliest infra asset at ATM Site.
It is the most critical component to energy security and Business continuity strategy.
However Batteries are not tested during commissioning or before Acceptance because  of Logistic and  implementation challenges.
Vendors offer 3 year warranty and Batteries are replaced every 3 years what-ever  may be its health.


Why Replace Battery Every 3 Yrs ?
If Design Life of Battery is 10 years, service life expectancy is about 6 to 8 years, Why are battery bank as a       whole replaced every 3 yrs.?

 
Can’t the Batteries be tested remotely for specified Backup & its Health before acceptance?


Monitoring Charging parameters and Health of Battery triggers proactive actions that can extend the Service life of Battery Bank and postpone its replacement by 2~3 yrs.  (40% Reduction in Replacement cost . Improves  Over all Break even by about 6 months or 9% improvement in IRR)


Battery Health Monitoring
Smart ATM Infra monitors the Vital Parameters of Battery 24 x7 and alerts the User  predictively on the State of  Health (SOH ) & State of Charge (SOC) of the Battery Bank.
  
Parameters Monitored:
Charging/Discharging Voltages
Charging Current
Load Current.
Depth of Discharge.
Cycle Count
Cycle vise AH in & AH out
Ambient Temperature


Incident Management  (1)
If ATM is not communicating to Bank Switch it could be due to :-
a) Machine issue
b) Communication Equipment  Issue.
c) UPS /Battery Issue
d) Extended outage of power.


Lack of Remote Visibility poses challenge in assigning the call promptly to the correct Vendor.


Results in extended resolution time and strains relationship with Vendors.       ( an analysis by UPS vendor      shows 27% call logged was not related to power, 8% call were  not their sites. 51% calls were due to site issue)


Incident Management  (2)
SOP of reporting to Help Desk and Incident Management of Assets like AC’s,  Lights, Signages has huge  Human dependency leading to large incidences of Missed Reporting or recording, delayed Escalations,  and open Calls.


Results in Customer/end user dissatisfaction, SLA penalties, Vendor Conflicts, Demoralized staff and escalations in administration cost.


Energy Bills- Its Cost
Hereto earlier Energy Bills were pass through. Now its Cost and need to bemonitored      and controlled.

Monitoring & Controlling Usage of ACs based on temperature, time of day & Season can help reduction of Energy Bills by up to 30% ( Rs 1800 to 2000/- pm per site)
Monitoring Power consumption 24x7 will trigger corrective actions at inefficient or rouge sites. 


 
Ideas Smart ATM Infrastructure

Monitors :
  UPS Status
  Battery Health
  Power Consumptions
  Connectivity (optional)
  Temperature
  Alarms & Alerts
  Mains OV/UV             
  Mains Fail
  Battery Low
  Battery Health Check Rqd.
  Charging Current  fault
  UPS Fault
  Over Temperature


Controls:        

Remote switching   On/Off  - of   AC, Lights, Signage

Power Reboot OTA


OPTIONAL ADD  ONs :

Extension of Site Alarms like Door Open, Smoke Sensor, Vibration Sensor, Occupancy Sensor, Camera etc. to Control   Center.


Fault / Incident Management

Automated Call routing and escalations  with alarm acknowledge and call  closure.


MIS Reports


Site wise/ cluster wise/ State wise-   Day wise/ month wise/ Year wise    report on


Alarm management & Up-Time Report , Power Availability Report , Power Consumption  Report.